Keysight 34970a 34972a documentation agilent 34970a 72a command reference keysight 34970a 34972a. The 34980 extends the capability for medium to large scale applications. Hp agilent diagrams, schematics and service manuals download for free. Square brackets indicate optional keywords or parameters. A vertical bar separates multiple parameter choices for a given command string. Choose from eight optional plugin modules to create a compact data logger, fullfeatured data.
The keysight 34903a is a generalpurpose switch module for the 34970a 34972a data acquisitionswitch unit. Keysight 34901a 20 channel multiplexer 24wire module for 34970a 34972a data acquisitionswitch unit. Keysight 34970a 34972a documentation keysight 34972a web interface programming examples contact keysight technologies trademarks. We have used agilent 34972a data loggers data acquisitionswitch unit available. Get price, programming manual, and more data from valuetronics. Handbuch keysight technologies 34970a 34972a switch datatec. Each input channel can be configured independently to measure one of 11 different functions.
Episode 7 connecting the 34970a to pc via gpib interface by. This section is only an overview and does not give all of the details you will need to write your own application programs. The agilent keysight 34970a data acquisition switch unit includes three slots for plugin modules in a mainframe plus a 6. Hi, i just bought a sick 34970a with a 901 and a 907 for 200 with shipment. Im waiting for the replacement parts, meanwhile im playing with it via the gpib interface im. Keysight 34970a data acquisitionswitch unit family 34970a 34972a technical overview.
The following command sets the temperature units to f on channels 12. The internal autoranging dmm directly measures 11 different functions, eliminating the need for expensive external signal conditioning. And our unique design allows complete perchannel configurability for maximum flexibility and quick, easy set up. This help file contains reference information to help you program the keysight 34970a 34972a over a remote interface using the programming language. Each channel can be configured independently to measure one of 11 different functions without the added cost or hassles of signalconditioning accessories. Customcal offers discount test equipment repairs service and calibrations on agilent 34970a, including hp agilent 34971a. Choose from eight optional plugin modules to create a. The agilent 34970a is easy to use for amultitude of data logging and monitoring applications, either standalone or with a computer.
The agilent 34401a digital multimeter provides protection circuitry to prevent damage to the instrument and to protect against the danger of electric shock, provided the protection limits are not exceeded. It has 20 independent singlepole, doublethrow spdt relays and is used to cycle power to products under test, control indicator and status lights, and to actuate external power relays and solenoids. Data acquisition 34970a, 34972a, benchvue keysight general purpose instruments. Keysight 34970a data acquisitionswitch unit family overview. Simplified programming overview this section gives an overview of the basic techniques used to program the hp 34970a over the remote interface. Itsflexible, modular design makes itscalable from 20 to 120 channels, and lets you add actuator, digital io, and analog output channels for simple control.
This is a genuine hewlett packard agligent 34970a data acquisition switch service guide manual printed in nov. Find great deals on ebay for agilent 34970a and agilent 34903a. Keysight agilenthp 34972a lxi data acquisition data. The keysight 34970a data acquisition data logger switch consists of a threeslot mainframe with a builtin 6 12 digit digital multimeter. For further information on programming the instrument, see chapter 5 in the.
This manual contains super illustrations and diagrams as well as having indepth operating, maintenance, calibration, and servicerepair information for these hp power supplies. Environmental condition requirement temperature operating condition 0 c to 55 c humidity operating condition. The 34901a module for the 34970a 34972a data acquisitionswitch unit is the most versatile multiplexer for general purpose scanning. This product features builtin lan and usb interfaces so you can easily connect to a pc or laptop without needing to purchase additional io cards or converter interfaces. Scpi, hp 3478a, and fluke 8840 reading rates up to readings per second storage for up to 512 readings limit testing with passfail signals optional hp 34812a benchlinkmeter software for microsoft windowstm hp 34401a multimeter. Agilent 34970a72a command reference keysight 34970a. Whether you use gpib, rs232, lan or usb interfaces. It has a sick display at least one of the 2 flv drivers is dead, and the display itself is a quite dim. Agilent 34970a is a highperformance, lowcost data acquisition and switching mainframe idea for data logging, data acquisition, and general purpose switching and control applications. Driver for hp 34970a ni community national instruments. The keysight 34970a data acquisition data logger switch unit consists of a threeslot mainframe with a builtin 6 12 digit digital multimeter. Free hp agilent diagrams, schematics, service manuals. The 34970a manual says both the measure and configure commands reset all measurement parameters to their default values in other words, what i am seeing is what the manual says should happen.
Introduction to the command language commands by subsystem. Hp34970a configuration via rs232 ni community national. Keysight 34970a data acquisitionswitch unit testequity. We have 1 hp 34970a manual available for free pdf download. We are new to labview and need basic help with getting it to work with our equipment.
New plus much more sophisticated software program systems are popping out that new plus much more sophisticated software program systems are popping out that download something is that to be vigilant about the reputation of the host. Consult the labview serial port manual for more information. Agilent 33220a 20 mhz function arbitrary waveform generator users guide publication number 3322090002 order as 3322090100 manual set. The new 34972a offers lan and usb so customers can easily connect, con. This manual contains getting started, configuration, programming and specifications for the 34970a. Standard connectivity to the pc whether you use gpib, rs232, lan or usb interfaces, the. Hp 34970a manuals manuals and user guides for hp 34970a. Keysight technologies 34901a multiplexer, 300v, 1a, 20. To ensure safe operation of the instrument, do not exceed the protection limits shown on the front and rear panel, and defined as follows. Hp benchlink data logger software advanced tcpip data logger advanced tcpip data logger brings you a convenient and effective tool that can collect network data from any device or instrument in real time, send and receive serial data over the internet or your lan. Measurements you can trust agilent took the measurement engine from their bestselling benchtop dmm and embedded it inside a 3slot cardcage. Itslike having an independent, highperformance dmm behind each channel. Hp benchlink data logger software free download hp.
Cut and pasted from the back of the 34970a user manual as visual basic example. The table below shows the general environmental requirements for this instrument. Intuitive user interface with knob for quick channel selection, menu navigation, and data. Keysight 34970a data acquisition data logger switch consists of a threeslot mainframe with a builtin 6 12 digit digital multimeter. Agilent 34970a, battery replacement and repair page 2. Simple things like onmodule screwterminal connectors, builtin thermocouple reference junctions, well organized user documentation full of examples and hints.
Keysight 34970a34972a over a remote interface using the programming language. Agilent 34970a programming guide pdf complete igmundesse. If the selftest fails, see the 34970a service guide for instructions on returning the. Keysight 34970a 34972a service guide 7 environmental conditions the 34970a 34972a is designed for indoor use and in an area with low condensation. Eight available types of plugin modules can be added to create a data logger, data acquisition system or switching. The following conventions are used for scpi command syntax for remote interface programming. Hpagilent 34970a data acquisitionswitch unit tested and. Agilent performance at a fraction of the cost of other. Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use.
1062 93 1107 431 1180 984 45 737 454 301 22 1312 17 1118 681 919 936 575 392 1478 573 1332 1210 1224 440 1459 561 663 624 43 517 703 1494 1076 600 715 940 1387 621 929 1152 1383 693 36 488 1128 221 1159 111